The LoCI Sentry measurement device is installed along landfill header infrastructure, dividing the wellfield into sections to monitor overall gas quality to the flare or beneficial use project.
Data from the Sentry empowers management teams with comprehensive insights into regional wellfield performance, helping to inform and support daily operations.
The LoCI Sentry remotely monitors:
Additional Technical Specifications
Calibration
Gas sensors are initially calibrated during manufacturing and auto-calibrated every 14 days unless otherwise specified, minimum
annually.
Power
Solar with rechargeable battery or optional AC power
Battery Capacity
>3 weeks at default measurement frequency
Default Measurement Frequency
3 Hours
Minimum Measurement Frequency
15 minutes (uses AC power)
Rated Temperatures
Operating range of -40°F to 122°F (-40°C to
50°C); maximum process temperature of 140°F (60°C
Connectivity
Cellular communication or wireless gateway
External Signal Compatibility
4–20 mA, digital
Install Location
Header or other piping infrastructure with two sample ports, minimum 12” apart
Installations at LoCI's Discretion
Corrosive locations with >10,000 ppm H2S; locations with solvent concentrations >10,000 ppb; not intended for locations with standing liquids.
Talk with our Team about Sentry Deployment and Pricing for Your Site