The 8.0 is the latest generation of the field devices at the heart of LoCI's real-time data and control system, including both the Controller, our wellhead-mounted measurement and active flow control device, and the Sentry, our header-mounted gas analysis device.
This design was built in direct response to what we heard from you. Customers told us that they wanted the option to service and maintain their LoCI devices themselves. With the 8.0, we re-engineered the device from the inside out, making hands-on maintenance possible without compromising performance. Teams who like to be hands-on in their wellfield now can be, and teams who'd rather leave it to us still have LoCI field service and 24/7/365 support on call.
|
LoCI 8.0 |
LoCI 7.0 |
|
|
Measurement & Control Performance |
||
|
Methane tolerance |
±0.50% (vol) |
±0.50% (vol) |
|
Carbon dioxide tolerance |
±0.50% (vol) |
±0.50% (vol) |
|
Oxygen tolerance |
±0.1% (vol) |
±0.1% (vol) |
|
Balance gas tolerance |
±1.25% (vol) |
±1.25% (vol) |
|
Flow tolerance * |
±2 SCFM (10–120 SCFM) / ±3 SCFM (<10 SCFM) |
±2 SCFM (10–120 SCFM) / ±3 SCFM (<10 SCFM) |
|
Flow Control |
Identical precision-controlled valve regulation |
Identical precision-controlled valve regulation |
|
External signal integration (4–20 mA) |
✓ |
✓ |
|
Operation & Connectivity |
||
|
Measurement cycles |
15min+ (hardwired) 15min+ (on battery/solar)
|
15min+ (hardwired) 1hr+ (on battery/solar) |
|
Device connection |
Wireless handheld UI — Bluetooth-enabled phone, laptop, or optional LoCI service tablet |
Hardwired handheld UI |
|
Power module |
Smaller, lighter design |
Standard |
|
Weather Resistant Design |
Enhanced |
Standard and Enhanced Available |
|
Maintenance & Support |
||
|
Dedicated LoCI Field Support Service |
✓ |
✓ |
|
24/7/365 customer support line |
✓ |
✓ |
|
LoCI Certification Operator Training |
Everything included in 7.0, plus:
NEW • Gas sensors NEW • Pressure sensor NEW • Cell modem NEW • Bluetooth module NEW • Power reset |
• Electronics module |
*Flow specifications apply to the Controller configuration (2″ wellheads).
†More frequent measurement cycles increase power draw and reduce battery runtime between charges.
Everything that makes the data trustworthy. Gas composition accuracy, flow accuracy, and control system performance are identical between the 8.0 and 7.0 generations. Methane and carbon dioxide measured to ±0.50%, oxygen to ±0.25%, and flow to ±2 SCFM across the standard range. The 8.0 also retains full compatibility with external 4–20 mA devices like flow meters and gas chromatographs.
Not at all. Your devices deliver the same gas composition accuracy, flow accuracy, and control performance as the 8.0, and they remain fully serviced and supported by LoCI. The 7.0 is a mature, field-proven platform. The first 7.0 devices, installed in late 2020, are still operating in the field today. The changes in the 8.0 are about serviceability and connectivity, not measurement quality. Your data, your WellWatcher® experience, and your support don’t change.
Yes, fully. Every LoCI device in the field, regardless of generation, is backed by LoCI field service and our 24/7/365 customer support line. That doesn’t change with the 8.0s.
All new device shipments are 8.0s. If you’re interested in adding 8.0 devices to your site or have questions about upgrading your 7.0s, please reach out to sales@locicontrols.com, and we’ll walk through the best path for your operation.
All new device shipments will be the 8.0 generation beginning July 1, 2026.
Our team is here for them, whether you’re running 7.0s, planning for 8.0s, or just getting started with real-time wellfield control. Fill out the form below and we’ll be in contact with you shortly.